Motor Rewinding Procedures
- Old coils are removed by heating the stationary part of the motor (stator) in an oven. The stator is kept in the oven at temperature of 650 degrees Fahrenheit for at least 10 hours or until the winding insulation turns to ash.
- New coils are traditionally wound by hand by a technician on a coil winding machine. The technician controls the wire tension, layering and number of turns on the coil, although there is also a mechanical counter on the machine.
- The newly rewound coil is warmed in an oven, immersed in an epoxy varnish and baked in an oven at a temperature of 300 degrees Fahrenheit for at least four hours. This procedure is known as dip and bake.